fieldpoc/docs/reference/controller.md

1.2 KiB

FieldPOC controller

The FieldPOC controller is an interactive console to help managing the current state of the FieldPOC system.

Connect to it via the IP address von port set in the FieldPOC configuration with telnet.

Commands

Help

help

Show help info.

Show handlers

handlers

Show currently running handlers

Reconfigure all components

sync

Notify all parts of FieldPOC to check configuration of connected components and update it.

Show queue stats

queues

Reload configuration

reload

Read FieldPOC configuration file and apply it.

Bind extension to DECT device

claim <ext> <token>

  • ext is the current extension number of the DECT device.
  • token is the dect_claim_token of the extension that should get applied.

This works because newly connected DECT phones get a temporary number assigned. This temporary number is usually the current number. But it is possible to use any extension, so the extension for a device can be changed any time.

Disconnect

exit

Disconnect telnet session.

Stop controller

stop

Shutdown the controller, but FieldPOC continues running.