1.2 KiB
1.2 KiB
FieldPOC controller
The FieldPOC controller is an interactive console to help managing the current state of the FieldPOC system.
Connect to it via the IP address von port set in the FieldPOC configuration with telnet
.
Commands
Help
help
Show help info.
Show handlers
handlers
Show currently running handlers
Reconfigure all components
sync
Notify all parts of FieldPOC to check configuration of connected components and update it.
Show queue stats
queues
Reload configuration
reload
Read FieldPOC configuration file and apply it.
Bind extension to DECT device
claim <ext> <token>
ext
is the current extension number of the DECT device.token
is thedect_claim_token
of the extension that should get applied.
This works because newly connected DECT phones get a temporary number assigned. This temporary number is usually the current number. But it is possible to use any extension, so the extension for a device can be changed any time.
Disconnect
exit
Disconnect telnet session.
Stop controller
stop
Shutdown the controller, but FieldPOC continues running.